Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 736
Filtrar
1.
J Drugs Dermatol ; 23(4): 249-254, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38564386

RESUMO

BACKGROUND: Micro-focused ultrasound with visualization (MFU-V) delivers energy to specific soft tissue layers beneath the epidermis with the ability to lift and tighten the lower face and neck.  Objective: To determine the efficacy of microfocused ultrasound with visualization (MFU-V) using a standard treatment line protocol versus a customized treatment line protocol based on the patient's unique anatomy targeting the superficial muscular aponeurotic system and fibrous septae for lifting and tightening of the lower face and neck. METHODS: This was a single-center, prospective, randomized, investigator-blinded clinical trial. 51 subjects were randomized to receive a single treatment of MFU-V targeting the lower face and neck using either a standard or custom treatment protocol.   Results: Subjects in both standard and custom treatment groups noted a greater than one-point improvement in jawline laxity. Three-dimensional photography measurements also demonstrated lifting of the lower face and neck in both treatment groups. CONCLUSION: Custom and standard treatment MFU-V protocols produce a safe and effective treatment for tightening and lifting the lower face and neck. Custom treatment protocols aid in maximizing results for patients with variations in the anatomy of the lower face and neck.  J Drugs Dermatol. 2024;23(4):7647.     doi:10.36849/JDD.7647.


Assuntos
Técnicas Cosméticas , Ritidoplastia , Envelhecimento da Pele , Terapia por Ultrassom , Humanos , Ritidoplastia/métodos , Terapia por Ultrassom/efeitos adversos , Terapia por Ultrassom/métodos , Estudos Prospectivos , Ultrassonografia , Resultado do Tratamento , Pescoço/diagnóstico por imagem , Satisfação do Paciente , Ensaios Clínicos Controlados Aleatórios como Assunto
2.
J Neurol ; 271(3): 1462-1468, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38032371

RESUMO

BACKGROUND: Transcranial Pulse Stimulation (TPS) has been recently introduced as a novel ultrasound neuromodulation therapy with the potential to stimulate the human brain in a focal and targeted manner. Here, we present a first retrospective analysis of TPS as an add-on therapy for Parkinson's disease (PD), focusing on feasibility, safety, and clinical effects. We also discuss the placebo response in non-invasive brain stimulation studies as an important context. METHODS: This retrospective clinical data analysis included 20 PD patients who received ten sessions of TPS intervention focused on the individual motor network. Safety evaluations were conducted throughout the intervention period. We analyzed changes in motor symptoms before and after TPS treatment using Unified Parkinson's Disease Rating Scale part III (UPDRS-III). RESULTS: We found significant improvement in UPDRS-III scores after treatment compared to baseline (pre-TPS: 16.70 ± 8.85, post-TPS: 12.95 ± 8.55; p < 0.001; Cohen's d = 1.38). Adverse events monitoring revealed no major side effects. CONCLUSION: These preliminary findings suggest that TPS can further improve motor symptoms in PD patients already on optimized standard therapy. Findings have to be evaluated in context with the current literature on placebo effects.


Assuntos
Doença de Parkinson , Terapia por Ultrassom , Humanos , Doença de Parkinson/terapia , Estudos Retrospectivos , Terapia por Ultrassom/efeitos adversos , Ultrassonografia , Encéfalo
3.
Medicina (Kaunas) ; 59(7)2023 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-37512146

RESUMO

Background and Objectives: Digital ulcers (DUs) are the most common complication in patients with Systemic Sclerosis (SSc). They cause pain with hand dysfunction and negatively impact activities of daily and working life. Our study aims to evaluate the efficacy of a combined treatment of manual therapy and ultrasound therapy in SSc patients with ischemic DU (IDU) compared to manual therapy alone. Materials and Methods: We conducted a before-and-after study (non-randomized study). We enrolled a consecutive series of IDU patients undergoing rehabilitation treatment and divided them into two groups: a treatment group consisting of patients undergoing a combination of manual therapy and US water immersion and a standard care group consisting of patients subjected to manual therapy alone. At the time of the first visit (T0) and at the end of the 4-week rehabilitation period (T1), we evaluated functional capacity, pain intensity, ulcer evolution, and quality of life. Results: In the treatment group, we observed a statistically significant improvement in the functional capacity of the hand (DHI: 28.15 ± 11.0 vs. 19.05 ± 8.83; p < 0.05), pain (NRS: 5.55 ± 1.2 vs. 2.9 ± 1.09; p < 0.05), and PSST score (24.4 ± 4.0 vs. 16.2 ± 2.36; p < 0.05). In the standard care group, we observed a statistically significant improvement only for the functional capacity of the hand (DHI: 28.85 ± 9.72 vs. 22.7 ± 7.68; p < 0.05). Finally, from the comparison between the treatment group and the standard care group, we observed statistically significant improvements in pain (2.9 ± 1.09 vs. 4.5 ± 1.07; p < 0.05) and in the PSST scale (16.2 ± 2.36 vs. 20.4 ± 4.02; p < 0.05). Furthermore, at the end of treatment in the treatment group, 15 ulcers (62.5%) were completely healed, while in the standard care group, only 3 ulcers were completely healed (14.3%). Conclusions: Combined treatment with manual therapy and ultrasound therapy appears to be useful in the management of IDU in patients with scleroderma.


Assuntos
Manipulações Musculoesqueléticas , Escleroderma Sistêmico , Úlcera Cutânea , Terapia por Ultrassom , Doenças Vasculares , Humanos , Úlcera/complicações , Qualidade de Vida , Imersão/efeitos adversos , Dedos , Úlcera Cutânea/terapia , Úlcera Cutânea/complicações , Escleroderma Sistêmico/complicações , Escleroderma Sistêmico/terapia , Terapia por Ultrassom/efeitos adversos , Manipulações Musculoesqueléticas/efeitos adversos , Dor
4.
J Cosmet Dermatol ; 22(10): 2671-2676, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37128835

RESUMO

BACKGROUND: Microfocused ultrasound with visualization (MFU-V) delivers focused ultrasound energy to heat tissue and has emerged as a fast and effective noninvasive method for treating skin laxity. After obtaining approval in 2009 by the Food and Drug Administration, satisfactory feedback was recorded using several scoring systems for MFU-V treatment for facial and neck laxity. AIM: To evaluate the efficacy and satisfaction rates of MFU-V for facial and neck laxity treatment by providing a basis for developing a validated scoring system for MFU-V treatment. METHOD: A constrictive survey was carried out by selecting relevant publications on MFU-V treatment of facial and neck laxity using PubMed, Medline, and Embase electronic databases from January 2017 to March 2022. RESULTS: Of the 11 original articles used in this review, the majority of the scoring methods used were the subjective global aesthetic improvement scale and the 5-point scale rating global aesthetic improvement in appearance. Around half of the patients were described as much improved or very much improved on days 30 and 90, while most returned to baseline on Day 360. Most of the adverse events reported were mild bruising, redness, and pain. None of the patients reported serious adverse events. A burn occurred in one case because of improper application of the probe. CONCLUSION: The MFU-V provides excellent and promising responses for treating facial and neck laxity. A few mild events were observed, such as erythema, pain, edema, and injection-site induration, all of which resolved within approximately 2-3 days.


Assuntos
Técnicas Cosméticas , Ritidoplastia , Envelhecimento da Pele , Terapia por Ultrassom , Humanos , Satisfação do Paciente , Terapia por Ultrassom/efeitos adversos , Terapia por Ultrassom/métodos , Ultrassonografia , Ritidoplastia/métodos , Eritema/etiologia , Pescoço , Resultado do Tratamento , Técnicas Cosméticas/efeitos adversos
5.
Artigo em Inglês | MEDLINE | ID: mdl-36674277

RESUMO

Objective: to systematically review the efficacy of microfocused ultrasound (MFU) for facial skin tightening. Methods: A systematic search was performed (Pubmed, Embase) to assess the efficacy of single MFU treatments for facial skin tightening. Eligible studies included randomised controlled trials, controlled trials, cohort studies and case series (n ≥ 10). Objective and subjective outcomes were assessed. Results: A total of 693 studies were identified of which 16 studies were eligible. All the studies involved female patients. MFU is capable of tightening the skin, as observed in studies measuring the results of brow lifts (0.47−1.7 mm) and submental lifts (measured as a 26−45 mm2 reduction in the submental area on lateral photographs). Data from the Global Aesthetic Improvement Scale (GAIS) were pooled, and the day 90 pooled subjective investigator reported scores (IGAIS) (n = 337) showed that 92% of the patients demonstrated an improvement in skin tightening and/or in wrinkle reduction which continued up to one year. Longer-term follow-up data are not available. The patient-reported pooled scores (SGAIS) (n = 81) showed that the skin improvements were mild and continued to increase from 42% (90 days) to 53% (360 days) post-treatment. The MFU treatment was moderately painful and caused transient erythema with or without oedema. Other adverse effects were rare (2%), including dysesthesia (numbness or hypersensitivity), bruising and stinging, mandibular burns, striations and contact dermatitis. Various device settings, treatment protocols and energies were applied. Excessive skin laxity and a BMI > 30 were posed as relative contraindications for MFU treatment because positive results declined with an increase in laxity and BMI. Conclusions: MFU treatment is effective in tightening female patients' mildly to moderately lax facial skin. Future studies should focus on objective treatment outcomes, optimising treatment regimens and male patients.


Assuntos
Técnicas Cosméticas , Ritidoplastia , Envelhecimento da Pele , Terapia por Ultrassom , Humanos , Masculino , Feminino , Terapia por Ultrassom/efeitos adversos , Terapia por Ultrassom/métodos , Face , Ritidoplastia/efeitos adversos , Ritidoplastia/métodos , Ultrassonografia , Resultado do Tratamento , Dor/etiologia , Satisfação do Paciente , Técnicas Cosméticas/efeitos adversos
6.
J Orthop Sci ; 28(1): 239-243, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34872820

RESUMO

BACKGROUND: The factors for poor adherence to therapy in patients with postoperative fracture who are treated with low-intensity pulsed ultrasound remain unknown. Therefore, we designed a retrospective cohort study to determine the various factors for poorer adherence to therapy in patients with postoperative fracture who were treated with low-intensity pulsed ultrasound therapy. METHODS: We retrospectively analyzed the data of postoperative patients who underwent low-intensity pulsed ultrasound after fracture surgery from January 2010 to May 2019. The patients were categorized into two groups as follows: group G, including those with a good adherence rate (>72%), and group P, including those with a poor adherence rate (<72%). Factors, such as age, sex, how the rental cost of low-intensity pulsed ultrasound was paid (by the patients themselves or by the insurance company), living (alone or with someone), insurance claim item (fractures within 3 weeks after osteosynthesis or delayed or non-union fractures), low-intensity pulsed ultrasound device-type (earlier- or next-generation), duration of low-intensity pulsed ultrasound use, fracture site (upper or lower limb), frequency of hospital visits (regular or irregular), and employment status (employed/unemployed) were compared between groups G and P. RESULTS: In total, 96 patients (74 and 22 patients in groups G and P, respectively) who underwent low-intensity pulsed ultrasound were included in the study. Univariate analysis revealed that younger patients (P < 0.001) and patients who did not regularly visit the hospital (P = 0.024) were more likely to have poorer adherence to therapy. Multiple logistic regression analysis revealed that age was the only independent, pertinent factor for poorer adherence to therapy (odds ratio, 8.570; 95% confidence interval, 2.770-26.50; P < 0.001), with a cutoff value of 41 years. CONCLUSIONS: Younger age is a significant factor for poorer adherence in patients undergoing low-intensity pulsed ultrasound therapy.


Assuntos
Fraturas Ósseas , Terapia por Ultrassom , Humanos , Estudos Retrospectivos , Consolidação da Fratura , Terapia por Ultrassom/efeitos adversos , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/terapia , Fraturas Ósseas/etiologia , Ondas Ultrassônicas
7.
J Cereb Blood Flow Metab ; 42(7): 1322-1334, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35130767

RESUMO

The feasibility of transcranial sonothrombolysis has been demonstrated, although little is known about the relationships between thermal or mechanical mechanisms and thrombolytic outcomes. Therefore, the present study aims to reveal the effect and safety of temperature and ultrasound through in vitro and in vivo thrombolysis models. Artificial clots in microtubes were heated in a water bath or sonicated by ultrasound irradiation, and then clots weight decrease with rising temperature and sonication time was confirmed. In the in vitro thrombotic occlusion model, based on spot heating, clot volume was reduced and clots moved to the distal side, followed by recanalization of the occlusion. In the in vivo study, the common carotid artery of rats was exposed to a spot heater or to sonication. No brain infarct or brain blood barrier disruption was shown, but endothelial junctional dysintegrity and an inflammatory response in the carotid artery were detected. The present spot heating and ultrasound irradiation models seem to be effective for disintegrating clots in vitro, but the safety of the in vivo model was not fully supported by the data. However, the data indicates that a shorter time exposure could be less invasive than a longer exposure.


Assuntos
Terapia Trombolítica , Trombose , Terapia por Ultrassom , Animais , Fibrinolíticos/uso terapêutico , Ratos , Trombose/terapia , Ativador de Plasminogênio Tecidual , Terapia por Ultrassom/efeitos adversos
8.
Front Endocrinol (Lausanne) ; 12: 793431, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34899616

RESUMO

Technological advances in thyroid surgery have rapidly increased in recent decades. Specifically, recently developed energy-based devices (EBDs) enable simultaneous dissection and sealing tissue. EBDs have many advantages in thyroid surgery, such as reduced blood loss, lower rate of post-operative hypocalcemia, and shorter operation time. However, the rate of recurrent laryngeal nerve (RLN) injury during EBD use has shown statistically inconsistent. EBDs generate high temperature that can cause iatrogenic thermal injury to the RLN by direct or indirect thermal spread. This article reviews relevant medical literatures of conventional electrocauteries and different mechanisms of current EBDs, and compares two safety parameters: safe distance and cooling time. In general, conventional electrocautery generates higher temperature and wider thermal spread range, but when applying EBDs near the RLN adequate activation distance and cooling time are still required to avoid inadvertent thermal injury. To improve voice outcomes in the quality-of-life era, surgeons should observe safety parameters and follow the standard procedures when using EBDs near the RLN in thyroid surgery.


Assuntos
Monitorização Intraoperatória/métodos , Complicações Pós-Operatórias/prevenção & controle , Nervo Laríngeo Recorrente/cirurgia , Instrumentos Cirúrgicos/tendências , Tireoidectomia/tendências , Voz/fisiologia , Animais , Eletrocoagulação/efeitos adversos , Eletrocoagulação/tendências , Humanos , Complicações Pós-Operatórias/etiologia , Traumatismos do Nervo Laríngeo Recorrente/etiologia , Traumatismos do Nervo Laríngeo Recorrente/prevenção & controle , Instrumentos Cirúrgicos/efeitos adversos , Glândula Tireoide/inervação , Glândula Tireoide/cirurgia , Tireoidectomia/efeitos adversos , Resultado do Tratamento , Terapia por Ultrassom/efeitos adversos , Terapia por Ultrassom/tendências
9.
J Mater Sci Mater Med ; 32(12): 150, 2021 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-34874480

RESUMO

OBJECTIVES: The objective of the present work was to evaluate the ultrasonic agitation, time and vehicle (propylene glycol or distilled water) on the antimicrobial potential and penetrability of calcium hydroxide pastes on infected dentin by means of Confocal Laser Scanning Microscopy (CLSM) and microbiological culture (MC). MATERIALS AND METHODS: Dentin specimens were infected with Enterococcus faecalis using a new contamination protocol of 5 days. The specimens were divided into eight groups and dressed with the pastes for 7 or 15 days: G1) calcium hydroxide (CH) + propylene glycol (prop)/7 days (d), G2) CH + prop/7d + ultrasonic agitation (U), G3) CH + distilled water (dw)/7d, G4) CH + dw/7d + U, G5) CH + prop/15d, G6) CH + prop/15d + U, G7) CH + dw/15d, G8) CH + dw/15d + U. The ultrasonic activation was made for 1 min in both directions with a plain point insert. After medications removal, the images obtained by CLSM showed the viable (green) and dead (red) bacteria with Live and Dead dye. By the MC, the dentinal wall debris obtained by burs were collected for colony counts. For the penetration test, the Rodamine B dye was added to the CH pastes and analyzed by CLSM. RESULTS: The 7 and 15-days CH + prop+U pastes performed better antimicrobial efficacy, followed by the CH + dw+U/15d paste. CONCLUSIONS: All pastes demonstrated better penetration and antimicrobial activity against E. faecalis when agitated with ultrasound, even in periods of up to seven days. The propylene glycol vehicle showed better results. CLINICAL RELEVANCE: Agitation of the dressing that remains for less time inside the root canal can optimize the decontamination of endodontic treatment.


Assuntos
Hidróxido de Cálcio/farmacologia , Dente , Terapia por Ultrassom/efeitos adversos , Animais , Anti-Infecciosos/farmacologia , Hidróxido de Cálcio/farmacocinética , Bovinos , Cimentos Dentários/farmacocinética , Cimentos Dentários/farmacologia , Cavidade Pulpar/efeitos dos fármacos , Cavidade Pulpar/microbiologia , Enterococcus faecalis/efeitos dos fármacos , Enterococcus faecalis/crescimento & desenvolvimento , Testes de Sensibilidade Microbiana , Materiais Restauradores do Canal Radicular/farmacocinética , Materiais Restauradores do Canal Radicular/farmacologia , Irrigantes do Canal Radicular/farmacocinética , Fatores de Tempo , Dente/efeitos dos fármacos , Dente/metabolismo , Dente/microbiologia , Permeabilidade Dentária/efeitos dos fármacos , Ultrassom/métodos
10.
Dermatol Surg ; 47(12): 1595-1600, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34608087

RESUMO

BACKGROUND: Unwanted submental fat (SMF) is aesthetically unappealing, but methods of reduction are either invasive or lack evidence of their use. OBJECTIVE: The authors sought to evaluate the safety and efficacy of a novel triple-layer high-intensity focused ultrasound (HIFU) regimen for SMF reduction. METHODS: Forty Korean subjects with moderate/severe SMF were evaluated after receiving a session of triple-layer HIFU treatments (using 3.0-, 4.5-, and 6.0-mm focusing transducers). The objective evaluation based on the 5-point Clinician-Reported Submental Fat Rating Scale (CR-SMFRS) and patients' satisfaction based on the 7-point Subject Self-Rating Scale (SSRS) were determined 8 weeks after treatment. Three-dimensional image analysis was also performed. RESULTS: At the follow-up visit, the proportion of treatment responders defined as subjects with ≥1-point improvement in CR-SMFRS was 62.5%, and the proportion of patients satisfied with appearance of their face and chin (score ≥4 on the SSRS) was 67.5% of the total patients. The results of 3-dimensional analysis were consistent with clinical observations. Only mild and transient side effects were observed for some patients with no serious adverse effects. CONCLUSION: The triple-layer HIFU regimen including the novel 6.0-mm transducer has benefits for tightening and rejuvenation of the area with unwanted SMF, showing reasonable safety profiles.


Assuntos
Tecido Adiposo , Técnicas Cosméticas , Terapia por Ultrassom/métodos , Tecido Adiposo/diagnóstico por imagem , Tecido Adiposo/efeitos da radiação , Adulto , Queixo , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Terapia por Ultrassom/efeitos adversos
11.
Sci Rep ; 11(1): 19274, 2021 09 29.
Artigo em Inglês | MEDLINE | ID: mdl-34588588

RESUMO

Transcranial application of pulsed low-intensity focused ultrasound (FUS) modulates the excitability of region-specific brain areas, and anesthetic confounders on brain activity warrant the evaluation of the technique in awake animals. We examined the neuromodulatory effects of FUS in unanesthetized sheep by developing a custom-fit headgear capable of reproducibly placing an acoustic focus on the unilateral motor cortex (M1) and corresponding thalamic area. The efferent responses to sonication, based on the acoustic parameters previously identified in anesthetized sheep, were measured using electromyography (EMG) from both hind limbs across three experimental conditions: on-target sonication, off-target sonication, and without sonication. Excitatory sonication yielded greater amplitude of EMG signals obtained from the hind limb contralateral to sonication than that from the ipsilateral limb. Spurious appearance of motion-related EMG signals limited the amount of analyzed data (~ 10% selection of acquired data) during excitatory sonication, and the averaged EMG response rates elicited by the M1 and thalamic stimulations were 7.5 ± 1.4% and 6.7 ± 1.5%, respectively. Suppressive sonication, while sheep walked on the treadmill, temporarily reduced the EMG amplitude from the limb contralateral to sonication. No significant change was found in the EMG amplitudes during the off-target sonication. Behavioral observation throughout the study and histological analysis showed no sign of brain tissue damage caused by the acoustic stimulation. Marginal response rates observed during excitatory sonication call for technical refinement to reduce motion artifacts during EMG acquisitions as well as acoustic aberration correction schemes to improve spatial accuracy of sonication. Yet, our results indicate that low-intensity FUS modulated the excitability of regional brain tissues reversibly and safely in awake sheep, supporting its potential in theragnostic applications.


Assuntos
Atividade Motora/efeitos da radiação , Córtex Motor/efeitos da radiação , Tálamo/efeitos da radiação , Terapia por Ultrassom/métodos , Animais , Eletromiografia , Feminino , Modelos Animais , Atividade Motora/fisiologia , Córtex Motor/fisiologia , Ovinos , Tálamo/fisiologia , Terapia por Ultrassom/efeitos adversos , Ondas Ultrassônicas/efeitos adversos , Vigília
12.
Dermatol Surg ; 47(12): 1585-1589, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34417390

RESUMO

BACKGROUND: Ultrasound energy has been used for cutaneous rejuvenation, including treatment of fine lines and wrinkles. Ultrasound waves of high intensity can induce thermal injury in the dermis, which causes tissue coagulation and remodeling. OBJECTIVE: To examine the safety and utility of a novel ultrasound device that uses high-intensity, high-frequency, parallel ultrasound beams to improve fine lines and wrinkles of the face and neck. MATERIALS AND METHODS: A prospective, multicenter, clinical study investigated the utility of this novel ultrasound device to improve fine lines and wrinkles. Sixty subjects were enrolled for single treatment to the face and neck. RESULTS: Fifty-eight subjects completed the study. The mean age was 58 years, and 87.9% were women. Fitzpatrick skin Types I to VI were represented. Assessments compared 12-week follow-up with baseline. Two blinded reviewers agreed in identifying pretreatment and post-treatment photographs for 78% of subjects. There was significant improvement of 1 to 3 Fitzpatrick Wrinkle and Elastosis Scale units in 86% of subjects. For investigator global improvement scores, 88% of subjects had improvement. Overall, 72% of subjects noted improvement, and the majority were satisfied. There were no device-related adverse events. CONCLUSION: Treatment with a novel ultrasound device that uses high-intensity, high-frequency, parallel ultrasound beams safely improved the clinical appearance of fine lines and wrinkles of the face and neck.


Assuntos
Face , Pescoço , Envelhecimento da Pele/efeitos da radiação , Terapia por Ultrassom/métodos , Adulto , Idoso , Técnicas Cosméticas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento , Terapia por Ultrassom/efeitos adversos
13.
Eur J Vasc Endovasc Surg ; 62(3): 463-468, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34303599

RESUMO

OBJECTIVE: Acute peripheral arterial occlusions can be treated by catheter directed thrombolysis (CDT). However, CDT is time consuming and accompanied by the risk of bleeding complications. The addition of contrast enhanced ultrasound and microbubbles could improve thrombus susceptibility to thrombolytic agents and potentially shorten treatment time with a lowered risk of bleeding complications. This article reports the outcomes of the safety and feasibility of this novel technique. METHODS: In this single arm phase II trial, 20 patients with acute lower limb ischaemia received CDT combined with an intravenous infusion of microbubbles and locally applied ultrasound during the first hour of standard intra-arterial thrombolytic therapy. The primary endpoint was safety, i.e., occurrence of serious adverse events (haemorrhagic complications and/or amputation) and death within one year. Secondary endpoints included angiographic and clinical success, thrombolysis duration, additional interventions, conversion, and quality of life. RESULTS: The study included 20 patients (16 men; median age 68.0 years; range, 50.0 - 83.0; and 40% native artery and 60% bypass graft). In all patients, the use of microbubble contrast enhanced sonothrombolysis could be applied successfully. There were no serious adverse events related to the experimental treatment. Duplex examination showed flow distal from the occlusion after 23.1 hours (range 3.1 - 46.5) with a median thrombolysis time of 47.5 hours (range 6.0 - 81.0). The short term ABI and pain scores significantly improved; however, no changes were observed before or after thrombolysis in the microcirculation. Overall mortality and amputation rates were both 2% within one year. The one year patency rate was 55%. CONCLUSION: Treatment of patients with acute peripheral arterial occlusions with contrast enhanced sonothrombolysis is feasible and safe to perform in patients. Further research is necessary to investigate the superiority of this new treatment over standard treatment.


Assuntos
Fibrinolíticos/administração & dosagem , Isquemia/terapia , Microbolhas , Doença Arterial Periférica/terapia , Terapia Trombolítica , Terapia por Ultrassom , Idoso , Idoso de 80 Anos ou mais , Feminino , Fibrinolíticos/efeitos adversos , Humanos , Isquemia/diagnóstico por imagem , Isquemia/fisiopatologia , Masculino , Microbolhas/efeitos adversos , Pessoa de Meia-Idade , Países Baixos , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Terapia Trombolítica/efeitos adversos , Fatores de Tempo , Resultado do Tratamento , Terapia por Ultrassom/efeitos adversos , Grau de Desobstrução Vascular
14.
Spine (Phila Pa 1976) ; 46(13): 845-851, 2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-34100838

RESUMO

STUDY DESIGN: Randomized Clinical Trial. OBJECTIVE: The aim of this study was to compare the efficacy of USBS with standard-of-care surgical instruments during posterior spinal fusion (PSF) in patients with adolescent idiopathic scoliosis (AIS) by evaluating the difference in estimated blood loss per level fused (EBL/level). SUMMARY OF BACKGROUND DATA: PSF surgery for AIS is often associated with high blood loss. Use of an ultrasonic bone scalpel (USBS) has been proposed to reduce blood loss during scoliosis surgery. METHODS: This was a single-blinded (patient-blinded), randomized, controlled superiority trial. We randomized 66 patients with AIS undergoing PSF to the control group (osteotome) or the experimental group (USBS). The primary outcome was intraoperative EBL/level obtained from red blood cell salvage reports. One-year follow-up was available for 57 of 62 (92%) of patients. RESULTS: EBL/level averaged 35 and 39 mL/level in the experimental and control groups, respectively [adjusted mean difference USBS - osteotome -8 mL/level, 95% CI: -16.4 to 0.3 mL/level, P = 0.0575]. There was no difference in curve correction [adjusted mean difference: -1.7%, 95% CI: -7.0 to 3.6%, P = 0.5321] or operative time [adjusted mean difference: -3.55 minutes, 95% CI: -22.45 to 15.46 min, P = 0.7089] between groups. Complications requiring change in routine postoperative care were noted in eight patients: two occurred in patients assigned to the experimental group and six occurred in patients assigned to the control group. CONCLUSION: There was no clinically significant difference in total blood loss, EBL/level, or complications between the two groups. In contrast to reports from other centers, at our high-volume spine center, USBS did not lead to reduced blood loss during PSF for AIS. These results may not be generalizable to centers with longer baseline operative times or higher baseline average blood loss during PSF for AIS.Level of Evidence: 1.


Assuntos
Perda Sanguínea Cirúrgica , Escoliose/cirurgia , Fusão Vertebral , Terapia por Ultrassom , Adolescente , Perda Sanguínea Cirúrgica/prevenção & controle , Perda Sanguínea Cirúrgica/estatística & dados numéricos , Humanos , Fusão Vertebral/efeitos adversos , Fusão Vertebral/métodos , Terapia por Ultrassom/efeitos adversos , Terapia por Ultrassom/métodos
15.
PLoS One ; 16(2): e0246261, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33571276

RESUMO

Ultrasound is considered a safe and non-invasive tool in regenerative medicine and has been used in the clinic for more than twenty years for applications in bone healing after the approval of the Exogen device, also known as low-intensity pulsed ultrasound (LIPUS). Beyond its effects on bone health, LIPUS has also been investigated for wound healing of soft tissues, with positive results for various cell processes including cell proliferation, migration and angiogenesis. As LIPUS has the potential to treat chronic skin wounds, we sought to evaluate the effects produced by a conventional therapeutic ultrasound device at low intensities (also considered LIPUS) on the migration capacity of mouse and human skin mesenchymal precursors (s-MPs). Cells were stimulated for 3 days (20 minutes per day) using a traditional ultrasound device with the following parameters: 100 mW/cm2 with 20% duty cycle and frequency of 3 MHz. At the parameters used, ultrasound failed to affect s-MP proliferation, with no evident changes in morphology or cell groupings, and no changes at the cytoskeletal level. Further, the migration and invasion ability of s-MPs were unaffected by the ultrasound protocol, and no major changes were detected in the gene/protein expression of ROCK1, integrin ß1, laminin ß1, type I collagen and transforming growth factor ß1. Finally, RNA-seq analysis revealed that only 10 genes were differentially expressed after ultrasound stimulation. Among them, 5 encode for small nuclear RNAs and 2 encode for proteins belonging to the nuclear pore complex. Considering the results overall, while the viability of s-MPs was not affected by ultrasound stimulation and no changes were detected in proliferation/migration, RNA-seq analysis would suggest that s-MPs do respond to ultrasound. The use of 100 mW/cm2 intensity or conventional therapeutic ultrasound devices might not be optimal for the stimulation the properties of cell populations. Future studies should investigate the potential application of ultrasound using variations of the tested parameters.


Assuntos
Células-Tronco Mesenquimais/efeitos da radiação , Terapia por Ultrassom , Ondas Ultrassônicas , Animais , Western Blotting , Movimento Celular/efeitos da radiação , Citoesqueleto/efeitos da radiação , Humanos , Camundongos , Microscopia de Fluorescência , Reação em Cadeia da Polimerase em Tempo Real , Transcriptoma/efeitos da radiação , Terapia por Ultrassom/efeitos adversos , Terapia por Ultrassom/métodos , Ondas Ultrassônicas/efeitos adversos , Cicatrização/efeitos da radiação
16.
Sci Rep ; 11(1): 4100, 2021 02 18.
Artigo em Inglês | MEDLINE | ID: mdl-33603035

RESUMO

Hepatocellular carcinoma (HCC) is a highly vascular solid tumor. We have previously shown that ultrasound (US) therapy significantly reduces tumor vascularity. This study monitors US-induced changes in tumor oxygenation on murine HCC by photoacoustic imaging (PAI). Oxygen saturation and total hemoglobin were assessed by PAI before and after US treatments performed at different intensities of continuous wave (CW) bursts and pulsed wave (PW) bursts US. PAI revealed significant reduction both in HCC oxygen saturation and in total hemoglobin, proportional to the US intensity. Both CW bursts US (1.6 W/cm2) and the PW bursts US (0.8 W/cm2) significantly reduced HCC oxygen saturation and total hemoglobin which continued to diminish with time following the US treatment. The effects of US therapy were confirmed by power Doppler and histological examination of the hemorrhage in tumors. By each measure, the changes observed in US-treated HCC were more prevalent than those in sham-treated tumors and were statistically significant. In conclusion, the results show that US is an effective vascular-targeting therapy for HCC. The changes in oxygenation induced by the US treatment can be noninvasively monitored longitudinally by PAI without the use of exogenous image-enhancing agents. The combined use of PAI and the therapeutic US has potential for image-guided vascular therapy for HCC.


Assuntos
Carcinoma Hepatocelular/terapia , Neoplasias Hepáticas Experimentais/terapia , Saturação de Oxigênio , Técnicas Fotoacústicas/métodos , Terapia por Ultrassom/métodos , Animais , Carcinoma Hepatocelular/irrigação sanguínea , Carcinoma Hepatocelular/patologia , Fígado/irrigação sanguínea , Fígado/patologia , Neoplasias Hepáticas Experimentais/irrigação sanguínea , Neoplasias Hepáticas Experimentais/patologia , Masculino , Camundongos , Camundongos Nus , Transplante de Neoplasias , Terapia por Ultrassom/efeitos adversos
17.
Ultrasound Med Biol ; 47(1): 131-138, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33092899

RESUMO

High-intensity ultrasound (US) ablation produces deeper myocardial lesions than radiofrequency ablation. The presence of intravascular microbubble (MB) contrast agents enhances pulsed-wave US ablation via cavitation-related histotripsy, potentially facilitating ablation in persistently perfused/conducting myocardium. US ablation catheters were developed and tested in the presence of MBs using ex vivo and in vivo models. High-frame-rate videomicroscopy and US imaging of gel phantom models confirmed MB destruction by inertial cavitation. MB-facilitated US ablation in an ex vivo perfused myocardium model generated shallow (2 mm) lesions and, in an in vivo murine hindlimb model, reduced perfusion by 42% with perivascular hemorrhage and inflammation, but no myonecrosis.


Assuntos
Ablação por Cateter/efeitos adversos , Fibrose/etiologia , Microbolhas/efeitos adversos , Microvasos/lesões , Terapia por Ultrassom/efeitos adversos , Animais , Ablação por Cateter/métodos , Camundongos , Imagens de Fantasmas , Terapia por Ultrassom/métodos
19.
J Vasc Interv Radiol ; 32(2): 256-261, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33303339

RESUMO

US-guided chemical component separation (CCS) of the abdominal musculature using botulinum toxin A can facilitate the surgical repair of large or complex hernias. Eight patients (2 women and 6 men with median age of 54 years [range, 34-78 years]) underwent preoperative US-guided CCS with hydrodissection before planned surgical repair of large or complex ventral (n = 4), inguinal (n = 2), and flank (n = 2) hernias by 2 interventional radiologists. Technical success rate of US-guided CCS procedures was 100%, and all patients achieved surgical closure a mean 34.1 days (range, 14-48 days) after US-guided CCS.


Assuntos
Músculos Abdominais/efeitos dos fármacos , Músculos Abdominais/cirurgia , Toxinas Botulínicas Tipo A/administração & dosagem , Hérnia Inguinal/terapia , Hérnia Ventral/terapia , Herniorrafia , Fármacos Neuromusculares/administração & dosagem , Terapia por Ultrassom , Adulto , Idoso , Toxinas Botulínicas Tipo A/efeitos adversos , Feminino , Hérnia Inguinal/diagnóstico por imagem , Hérnia Ventral/diagnóstico por imagem , Herniorrafia/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Fármacos Neuromusculares/efeitos adversos , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Terapia por Ultrassom/efeitos adversos
20.
Pak J Pharm Sci ; 33(3(Special)): 1397-1402, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-33361029

RESUMO

The primary objective of the present clinical trial was to evaluate efficacy and safety of tramadol versus prednisone in Chinese patients with carpal tunnel syndrome (CTS) diagnosed by ultrasonography. A total of 60 patients' diagnosed with moderate CTS based on a clinical and electrophysiological parameters were enrolled in this clinical trial. The patients were randomly assigned to one of two groups in allocation ratio of 1:1. Test group was given controlled release Tramadol (100 mg every 12 hours) and Reference Group received Prednisone 20 mg once daily for 2 weeks (14 days). Ultrasound therapy (UT) was given as adjuvant therapy in both the group. CTS were evaluated before and after treatment through clinical findings, Boston Carpal Tunnel Questionnaire, visual analog scale (VAS) and electrophysiological data. The results were evaluated with Student's t test and chi-squared. A statistically significant difference was observed between both the treatment group regarding Durkan's test, Phalen's test, VAS and electrophysiological data after treatment. Improvement in patients treated with tramadol was significantly higher compared to prednisone group in all clinical and electrophysiological parameters. The Boston Questionnaire showed better results in tramadol groups, with a significant improvement in the symptom severity scale (SSS; p<0.005) and functional status scale (FSS; p<0.005). The results of this clinical trial suggest that treatment of CTS with tramadol along with UT as adjuvant therapy was associated with a significant improvement of clinical and electrophysiological parameters compared to Prednisone.


Assuntos
Analgésicos Opioides/uso terapêutico , Síndrome do Túnel Carpal/terapia , Glucocorticoides/uso terapêutico , Prednisona/uso terapêutico , Tramadol/uso terapêutico , Terapia por Ultrassom , Analgésicos Opioides/efeitos adversos , Síndrome do Túnel Carpal/diagnóstico por imagem , Síndrome do Túnel Carpal/fisiopatologia , China , Terapia Combinada , Feminino , Glucocorticoides/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Prednisona/efeitos adversos , Fatores de Tempo , Tramadol/efeitos adversos , Resultado do Tratamento , Terapia por Ultrassom/efeitos adversos , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...